- Four-sided design accommodates four bushings that easily change out with a hex wrench
- Efficiently & precisely strip 600V secondary cable without damaging the conductor, even in cold climates
- Compatible square or chamfer cut bushings for stripping 45 mil to 95 mil secondary insulations with concentric, compressed or compacted conductors #6 AWG to 750 kcmil
- Guarded bushing cutting blades prevent injury
- TOOL BODY ONLY. If you would like to order bushings, please see the note below. You can also order the bushings separately using the links under the Bushing Sizes heading below.
NOTE: The 4×4 Plus is available with or without bushings. If you would like to order the 4×4 Plus with 4 bushings, please take a look at the available square or chamfer cut bushings from the bushings below and submit a Request for Quote. A Powertech Associates representative will get back to you within 24 hours.
Bushing Sizes:
Compatibility:
Conductor Type: | Concentric, Compressed, Compacted |
Cable Compatibility: | Secondary Distribution |
Cable Access: | End |
Min. Cable Outer Diameter: | #6 AWG |
Max. Cable Outer Diameter: | 750 kcmil |
Max. Voltage: | 600 V |
Insulation Thickness: | 45 mils, 60 mils, 80 mils, 95 mils |
Specifications:
Max. Capacity Bushings | 4 |
Comparison Chart:
Model | Part # | Item Type | Dimensions | Weight |
---|---|---|---|---|
4x4 Plus® | 36001H | Tool Body Only | 4.5″ x 5″ | 14 oz |